Telephone:
Toll Free in US only
(877) 446-1444

Outside the US
(941) 751-0588

Fax:
(941) 752-4738


Search Hurricane Medical Website
Ophthalmology Conventions:
ASCRS Annual Meeting
April 5-8, 2024
Boston Convention Center, Boston, MA
Booth Number: 2474
Home    Certificates    Products    Distributors    Catalog    Links    Contact Us
VITREORETINAL
Products designed specifically for posterior segment surgical procedures.
Dual Bore | Infusion |  High Viscosity |  Subretinal Fluid |  Micro tip Cannulas |  Viscodissectors
Dual Bore


  7528   Dual Bore Cannula
            23G (.60mm) Simultaneous infusion of
            liquids through center lumen and
            aspiration of fluid through a vent hole
            in the outer lumen.


  7529   Dual Bore Cannula
            20G (.90mm) Simultaneous infusion of
            liquids through center lumen and
            aspiration of fluid through a vent hole
            in the outer lumen.


7530  Dual Bore Cannula
25G (.50mm) Simultaneous infusion of liquids through center lumen and
aspiration of fluid through a vent hole in the outer lumen.
Infusion
Facilitates posterior segment infusion.


  7501  Infusion Cannula 2.5mm
           20G (.90mm) Flexible Tubing: 10in (25cm)


  7502  Infusion Cannula 4mm
           20G (.90mm) Flexible Tubing: 10in (25cm)



 7503  Infusion Cannula 6mm
           20G (.90mm)
           Flexible tubing: 10in (25cm)



 7524  Infusion Cannula 4mm
           23G (.60mm)
           Flexible tubing: 10in (25cm)


                                            7525  Infusion Cannula 6mm
                                     23G (.60mm) Flexible Tubing: 10in (25cm)
High Viscosity
Designed for injection of silicone oil and other viscous fluids.
Special high pressure tubing is attached to thinwall cannula. May also be used as standard infusion cannulas.


  7504  Viscous Infusion Cannula 4mm
           20G (.90mm); Tubing: 4in (10cm)


  7505  Viscous Infusion Cannula 6mm
           20G (.90mm); Tubing: 4in (10cm)


  7506  Viscous Infusion Cannula 4mm
           20G (.90mm); Tubing: 6in (16cm)


  7507  Infusion Cannula 6mm
           20G (.90mm); Tubing: 6in (16cm)
GO TO TOP OF PAGE
Subretinal Fluid
To aspirate fluid from subretinal space.
Soft flexible tips provide atraumatic entry through retinal or macular tears or holes.


 7725  Subretinal Fluid Cannula
          25G (.50mm) 1.5mm flexible tip extension
          Super thinwall inner diameter provides
          flow equivalent to 22 gauge
          (.70mm) cannula
          Overall length with tubing 1.5 in (31.5mm)


 7825  Subretinal Fluid Cannula
          25G (.50mm) 3mm flexible tip extension
          Super thinwall inner diameter provides
          flow equivalent to 22 gauge
          (.70mm) cannula
          Overall length with tubing 1.313 in (34mm)


 7723  Subretinal Fluid Cannula
          23G (.60mm) 1.5mm flexible tip extension.
          Overall length with tubing 1.5 in (32mm)


 7823  Subretinal Fluid Cannula
          23G (.60mm) 3mm flexible tip extension.
          Overall length with tubing 1.313 in (34mm)


                                            7526  Vitreoretinal Cannula
                                     23G (.60mm) with 39G (.09mm). 5mm Polymide tip extension.
GO TO TOP OF PAGE
Micro Tip Cannulas
Designed for injecting or aspirating subretinal fluid.
Micro tips for working around and through retinal and macular tears or holes with less chance of engaging the retina.


 7423  Vitreoretinal Cannula
          23G x 1.125 in (.60 x 28mm)
          Blunt tip cannula.


 7425  Vitreoretinal Cannula
          25G x 1.125 in (.50 x 28mm)
          Blunt tip cannula.


 7620  Vitreoretinal Cannula
          20G x 1.125 in (.90 x 28mm)


 7523  Vitreoretinal Brush
          23G (.60mm)
          3mm flexible tip extension.


 7920  Silicone Oil Cannula
          20G x .313 in (.90 x 8mm)


 7923  Silicone Oil Cannula
          23G x .313 in (.60 x 8mm)
          Blunt tip cannula.


  7925   Silicone Oil Cannula
             25G x 5/16 in (.50 x 8mm)
             Simultaneous infusion of liquids
             through center lumen and aspiration
             of fluid through a vent hole in
             the outer lumen.


  7623   Vitreoretinal Micropick
             23G x 1.25 in (.90mm x 32mm)
             Sharp,angled tip
            
            
            


                                            7623  Vitreoretinal Micropick
                                     23G x 1.25 in (.90mm x 32mm). Sharp,angled tip.
GO TO TOP OF PAGE
Viscodissectors
For dissection of vitreoretinal membranes using viscoelastic fluid.
A high pressure luer lock tubing set is attached to cannula. Tubing is 8 in (20cm) long; ID - .02 in (.50mm);
OD - .06 in (1.5mm) and capable of withstanding injections of viscoelastic fluids.


 7517  Vitreoretinal Viscodissector 90º
          20G (.90mm) cannula with 30G (.30mm) tip
          flattened. Angled 90º, 1mm from end


 7518  Vitreoretinal Viscodissector 70º
          20G (.90mm) cannula with 30G (.30mm) tip
          flattened. Angled 70º, 1mm from end


                                          7519  Vitreoretinal Viscodissector 45º
             20G (.90mm) cannula with 30G (.30mm) tip flattened. Angled 45º, 1mm from end
GO TO TOP OF PAGE

Home | Products | Certificates | Distributors | Our Catalog | Links | Contact Us
©2024 Hurricane Medical

WEB SITE DESIGN CREATED BY XU Shots